Low Ambient Temperature Heat Pump Factory – 10HP Low Ambient Temperature Heat Pump – solarshine

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Solar Hot Water Heater System, Solar Tank, Water Source Heat Pump Residential, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Low Ambient Temperature Heat Pump Factory – 10HP Low Ambient Temperature Heat Pump – solarshine Detail:

Description of low ambient temperature heat pump

Type

Low Ambient Temperature Air Source Heat Pump

Housing Material

Plastic, galvanized Sheet

Storage / Tankless

Circulation Heating

Installation

Freestanding, Wall Mounted / Freestanding

Use

Hot Water/floor Heating/ fancoil Heating And Cooling

Heating Capacity

4.5-20KW

Refrigerant

R410a/ R417a/ R407c/ R22/ R134a

Compressor

Copeland, Copeland Scroll Compressor

Voltage

220V 〜lnverter,3800VAC/50Hz

Power Supply

50/ 60Hz

Function

House Heating, Space Heating & Hot Water,Pool Water Heating, cooling And DHW

Cop

4.10-4.13

Heat Exchanger

Shell Heat Exchanger

Evaporator

Gold Hydrophilic Aluminum Fin

Working Ambient Temperature

Minus -25C- 45C

Compressor Type

Copeland Scroll Compressor

Color

White, Grey

Application

Jacuzzi Spa/ Swimming Pool,Hotel, Commercial And Industrial

Input Power

2.8-30KW

High Light

cold temperature heat pump, inverter air source heat pump

What’s the working principle of low ambient temperature air source heat pump?

The heat pump unit is a closed system composed of evaporator, condenser, compressor and expansion valve, which is filled with an appropriate amount of refrigerant.

The basic principle of heat pump operation is based on the principle of reverse Carnot cycle: the liquid refrigerant first absorbs the heat in the air in the evaporator and evaporates to form steam (vaporization), and the vaporization latent heat is the recovered heat. Then it is compressed into high-temperature and high-pressure gas by the compressor and enters the condenser to condense into liquid (liquefaction) to send the absorbed heat to the required heated pool water, The liquid refrigerant returns to the expansion valve after depressurization and expansion through the expansion valve, absorbs heat and evaporates to complete a cycle. In this way, it continuously absorbs the heat of the low-temperature source and outputs the heated swimming pool water to directly reach the predetermined temperature.

specification of low ambient temperature heat pump

Model

KDR-03

KDR-05S

KDR-05-G

KDR-07-G

KDR-10-G

KDR-15

KDR-20

KDR-25

HP

3 HP

5 HP

5 HP

7HP

10HP

15HP

20HP

25HP

Power supply

220V/380V

220V

380V

380V

380V

380V

380V

380V

Input power

2.8

4.2

4.7

5.2

9.2

13

18.5

20.5

Heating power output at different ambient tem.

(20℃)

10.8

16.2

18

20

35.4

50

71.2

78.9

(6/7℃)

9

13.7

15.3

16.9

30

42.3

60

66.6

(-6/7℃)

6.9

10.3

11.5

12.7

22.5

319

453

50.2

(-15℃)

5.9

8.8

9.9

10.9

19.3

273

38.9

43

(-20℃)

5.2

7.8

8.7

9.6

17

24

34.2

37.9

Cooling power output

8.0

12.0

13.4

14.8

26.2

37.1

52.7

68.4

Fan outlet direction

Side

Side

Side

Side

Side

Side

Top

Top

Vfaler connection

DN25

ON25

DN25

DN25

DN32

DN40

DN50

DN50

Fluid rate(M3/H)

2-3

4-5

5-6

5-7

7-10

12-15

15-20

20-25

Dimen -sion

(MM)

1152

1190

1190

1190

1350

1350

1800

1800

(MM)

422

425

425

425

645

645

1100

1100

(MM)

768

1240

1240

1240

1845

184S

2100

2100

WEIGHT (kg)

130

180

160

220

310

355

630

780


drawing of low ambient temperature heat pump

Compared with ordinary heat pumps, at – 10 ℃ and lower temperatures, the evaporation temperature is too low, resulting in less evaporation, resulting in less return air volume of the compressor, which affects the condensation and heat release. An injection enthalpy increasing branch connecting the compressor is added to the ultra low ambient temperature heat pump. When the return air of the compressor is insufficient, the injection enthalpy increasing branch will make up air for the compressor, so the heat release of the condenser will be increased, so it can still produce heat normally at very low temperature.


application of description of low ambient temperature heat pump


Product detail pictures:

Low Ambient Temperature Heat Pump Factory –  10HP Low Ambient Temperature Heat Pump  – solarshine detail pictures


Related Product Guide:

We normally think and practice corresponding towards the change of circumstance, and grow up. We aim at the achievement of a richer mind and body plus the living for Low Ambient Temperature Heat Pump Factory – 10HP Low Ambient Temperature Heat Pump – solarshine , The product will supply to all over the world, such as: Estonia, Johor, Los Angeles, We have got constantly insisted on the evolution of solutions, spent good funds and human resource in technological upgrading, and facilitate production improvement, meeting the wants of prospects from all countries and regions.
  • The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Laurel from Norwegian - 2017.12.09 14:01
    This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Chloe from Bangalore - 2017.04.28 15:45
    Write your message here and send it to us