25HP Low Ambient Temperature Heat Pump for Hospital

Short Description:

SolarShine’s 25HP Low ambient temperature air energy heat pump can produce heat well even in the environment of -25 degrees. It is not limited by low temperature environment, a wise choice for heating, hot water and floor heating in cold areas.


Product Detail

Product Tags

Description of low ambient temperature heat pump

Type

Low Ambient Temperature Air Source Heat Pump

Housing Material

Plastic, galvanized Sheet

Storage / Tankless

Circulation Heating

Installation

Freestanding, Wall Mounted / Freestanding

Use

Hot Water/floor Heating/ fancoil Heating And Cooling

Heating Capacity

4.5-20KW

Refrigerant

R410a/ R417a/ R407c/ R22/ R134a

Compressor

Copeland, Copeland Scroll Compressor

Voltage

220V 〜lnverter,3800VAC/50Hz

Power Supply

50/ 60Hz

Function

House Heating, Space Heating & Hot Water,Pool Water Heating, cooling And DHW

Cop

4.10-4.13

Heat Exchanger

Shell Heat Exchanger

Evaporator

Gold Hydrophilic Aluminum Fin

Working Ambient Temperature

Minus -25C- 45C

Compressor Type

Copeland Scroll Compressor

Color

White, Grey

Application

Jacuzzi Spa/ Swimming Pool,Hotel, Commercial And Industrial

Input Power

2.8-30KW

High Light

cold temperature heat pump, inverter air source heat pump

 

Hot water supply is the most basic service of the hospital just ike hotels and guesthouses, meanwhile hospital hot water does not have the so-called peak period, patients or doctors use hot water all the time. Therefore, the hospital must be able to ensure that there is stable hot water 24 hours a year. At present, hospital hot water generally uses air source heat pump. Low ambient temperature air source heat pump can help hospitals in cold areas maintain constant temperature hot water supply all year round, and achieve the goal of emission reduction and environmental protection.

The upgraded R410A environment-friendly refrigerant is adopted, which has higher density in low-temperature environment and significantly improves the heating capacity per unit volume. At - 7 - 0 , the heating efficiency is more than 50% higher than that of ordinary heat pump, and the heat pump can keep normal operation at - 25 °.

specification of low ambient temperature heat pump

Model

KDR-03

KDR-05S

KDR-05-G

KDR-07-G

KDR-10-G

KDR-15

KDR-20

KDR-25

HP

3 HP

5 HP

5 HP

7HP

10HP

15HP

20HP

25HP

Power supply

220V/380V

220V

380V

380V

380V

380V

380V

380V

Input power

2.8

4.2

4.7

5.2

9.2

13

18.5

20.5

Heating power output at different ambient tem.

(20℃)

10.8

16.2

18

20

35.4

50

71.2

78.9

(6/7℃)

9

13.7

15.3

16.9

30

42.3

60

66.6

(-6/7℃)

6.9

10.3

11.5

12.7

22.5

319

453

50.2

(-15℃)

5.9

8.8

9.9

10.9

19.3

273

38.9

43

(-20℃)

5.2

7.8

8.7

9.6

17

24

34.2

37.9

Cooling power output

8.0

12.0

13.4

14.8

26.2

37.1

52.7

68.4

Fan outlet direction

Side

Side

Side

Side

Side

Side

Top

Top

V\faler connection

DN25

ON25

DN25

DN25

DN32

DN40

DN50

DN50

Fluid rate(M3/H)

2-3

4-5

5-6

5-7

7-10

12-15

15-20

20-25

Dimen -sion

(MM)

1152

1190

1190

1190

1350

1350

1800

1800

(MM)

422

425

425

425

645

645

1100

1100

(MM)

768

1240

1240

1240

1845

184S

2100

2100

WEIGHT (kg)

130

180

160

220

310

355

630

780

Comprehensive advantages of low temperature heat pump:

1. Stable and reliable

The air source heat pump heating system equipped with EVI jet enthalpy increasing technologysolves the problems of low-temperature heating attenuation and too high compressor exhaust temperature. Even in the severe cold area of - 35 , the low-temperature air energy heat pump system still operates reliably and has strong heating.

2. Superior economic performance

Although the differences in maintenance structure between the South and the north, outdoor temperature and relative humidity, residents' habits and defrosting control have a great impact on the economy of unit operation, air source heat pump is still more economical and energy-saving than gas wall mounted boiler and electric heating, saving 15% - 70% of operation cost, whether replacing coal-fired boiler central heating or independent user heating, They are the preferred schemes for energy conservation and environmental protection.

3. Comfortable use experience

In the application of air energy heat pump heating in different climate zones, the temperature level in the user's room is well maintained. With good indoor system layout and design, the temperature gradient and fluctuation meet the requirements of ergonomics for comfort; In addition, the thermal comfort of floor radiant heating is better than that of radiator. It can get a comfortable and uniform thermal environment with low-temperature hot water. It is a good choice for a new type of comfortable heating mode.

Application Cases


  • Previous:
  • Next:

  • Write your message here and send it to us