15HP Low Ambient Temperature Air Source Heat Pump

Short Description:

SolarShine 15HP Low Ambient Temperature Air Source Heat Pump has the advantages of no waste gas, no waste residue, water and electricity separation, reliable and safe, high efficiency, energy saving and green environmental protection.


Product Detail

Product Tags

Description of low ambient temperature heat pump

Type

Low Ambient Temperature Air Source Heat Pump

Housing Material

Plastic, galvanized Sheet

Storage / Tankless

Circulation Heating

Installation

Freestanding, Wall Mounted / Freestanding

Use

Hot Water/floor Heating/ fancoil Heating And Cooling

Heating Capacity

4.5-20KW

Refrigerant

R410a/ R417a/ R407c/ R22/ R134a

Compressor

Copeland, Copeland Scroll Compressor

Voltage

220V 〜lnverter,3800VAC/50Hz

Power Supply

50/ 60Hz

Function

House Heating, Space Heating & Hot Water,Pool Water Heating, cooling And DHW

Cop

4.10-4.13

Heat Exchanger

Shell Heat Exchanger

Evaporator

Gold Hydrophilic Aluminum Fin

Working Ambient Temperature

Minus -25C- 45C

Compressor Type

Copeland Scroll Compressor

Color

White, Grey

Application

Jacuzzi Spa/ Swimming Pool,Hotel, Commercial And Industrial

Input Power

2.8-30KW

High Light

cold temperature heat pump, inverter air source heat pump

 

specification of low ambient temperature heat pump

Model

KDR-03

KDR-05S

KDR-05-G

KDR-07-G

KDR-10-G

KDR-15

KDR-20

KDR-25

HP

3 HP

5 HP

5 HP

7HP

10HP

15HP

20HP

25HP

Power supply

220V/380V

220V

380V

380V

380V

380V

380V

380V

Input power

2.8

4.2

4.7

5.2

9.2

13

18.5

20.5

Heating power output at different ambient tem.

(20℃)

10.8

16.2

18

20

35.4

50

71.2

78.9

(6/7℃)

9

13.7

15.3

16.9

30

42.3

60

66.6

(-6/7℃)

6.9

10.3

11.5

12.7

22.5

319

453

50.2

(-15℃)

5.9

8.8

9.9

10.9

19.3

273

38.9

43

(-20℃)

5.2

7.8

8.7

9.6

17

24

34.2

37.9

Cooling power output

8.0

12.0

13.4

14.8

26.2

37.1

52.7

68.4

Fan outlet direction

Side

Side

Side

Side

Side

Side

Top

Top

V\faler connection

DN25

ON25

DN25

DN25

DN32

DN40

DN50

DN50

Fluid rate(M3/H)

2-3

4-5

5-6

5-7

7-10

12-15

15-20

20-25

Dimen -sion

(MM)

1152

1190

1190

1190

1350

1350

1800

1800

(MM)

422

425

425

425

645

645

1100

1100

(MM)

768

1240

1240

1240

1845

184S

2100

2100

WEIGHT (kg)

130

180

160

220

310

355

630

780

What’s the core technology of SolarShine Low Ambient Temperature Air Source Heat Pump?

1Jet enthalpy increasing system

1) Jet enthalpy increasing system is a new system composed of jet enthalpy increasing compressor, jet enthalpy increasing technology and high-efficiency subcooler. The combination of these three technologies can provide high-efficiency performance. This is an organic whole, that is, the high-efficiency jet enthalpy increasing compressor, the economizer formed by the high-efficiency subcooler and electronic expansion valve and the high-efficiency heat exchanger together constitute the high-efficiency and energy-saving jet system.

2High efficiency heat exchanger

1) Compact structure and high efficiency

High efficiency heat exchange tube, the heat exchange area is 3.7 times that of smooth tube, and the heat transfer efficiency is greatly improved.

2) Countercurrent arrangement

The countercurrent arrangement of cooling water circuit and refrigerant circuit can ensure the undercooling of outlet refrigerant and improve the system efficiency;

3) Adapt to large inlet and outlet water temperature difference

It reduces the amount of condensate circulation, reduces the size of condensate water pipe and the specification of circulating pump; The pump power and operation cost are reduced;

4) Freeze washable

Spiral coil, smooth water flow, easy to implement freezing cleaning;

5) The clearance between the refrigerant circuit and the housing is small: it will not cause the retention of lubricating oil and can ensure the return of oil.

3Intelligent defrosting function

Advanced defrosting control mode ensures defrosting function and no wrong defrosting. Defrosting conditions:

1) Coil temperature < - 7 ;

2) Defrosting interval > 45min;

3) Heating capacity attenuation 20% (adjustable)